570160.1200 Black Fast Flash
An environmentally friendly and a lead-free flashing widths of 280mm, 370mm and 560mm and rolls 5 metres long Available in four colours, which complement most roof colours and provide an aesthetically pleasing finish dressing down perfectly to all roofing profiles. It has a fully adhesive base that makes it easy to install, requiring 50% less time than other lead based solutions. It can be installed on roofs with a minimum slope of 5°.
• Manufactured from a specially formulated polymer rubber reinforced with aluminium mesh that makes it the most flexible and easy to work with flashing solution.
Note:-
• Fast Flash can be used on metal roofs, tiles, polycarbonate, concrete, glass and polished wood.
• When used on vertical surfaces, such as, exposed brick, rough concrete or unpolished timber then a 25mm x 1mm aluminium strip is recommended to secure the top side of the membrane.
• Do not pre-stretch the membrane prior to installation.
• The Fast Flash membrane should be formed to the profile of the surface by hand or by using a roller. The use of any other tools or mechanically stretching the membrane prior to adhering the Fast Flash will void the warranty.
Installation Procedure
1. Before installing Fast Flash, make sure the roof is clean of dust and free of oils, grease, wax and detergents etc.
2. Cut the Fast Flash to length with roofing snips or a trade knife. Consider corners, change of direction and overlaps before cutting (See point 7 below)
3. Remove the backing paper to allow adhesion to the wall or the chimney etc.
4. The butyl adhesive backing has a 10 minute curing time, allowing adequate flexibility to reposition Fast Flash if required.
5. Once in correct position, remove the remaining backing paper and gently form the Fast Flash to the roof profile using your hands.
6. When required all lineal overlaps of Fast Flash must be 50mm in length & formed to the wall & roof profile in order to eliminate or minimise any gaps between the flashing and wall/tile.
7. Corners/change of direction - Using a trade knife, appropriately slice Fast Flash lengths to ensure a minimum corner/change in direction overlap of 40mm. Fold corner edges and form the roof profile in order to eliminate/minimise and gaps between the flashing and wall/tile.
8. Fast Flash is malleable and stretch-able, allowing easy folding around corners using hands.
9. When used on vertical surfaces with exposed brick or unpolished timber, a 25mm x 1mm Aluminium strip is recommended
10. For a professional finish, dress lightly using sand hammer.
For further Information go to https://3986358.app.netsuite.com/core/media/media.nl?id=4337732&c=3986358&h=c03bbfe8b13c8e70615b&_xt=.pdf
• Fast Flash can be used on metal roofs, tiles, polycarbonate, concrete, glass and polished wood.
• When used on vertical surfaces, such as, exposed brick, rough concrete or unpolished timber then a 25mm x 1mm aluminium strip is recommended to secure the top side of the membrane.
• Do not pre-stretch the membrane prior to installation.
• The Fast Flash membrane should be formed to the profile of the surface by hand or by using a roller. The use of any other tools or mechanically stretching the membrane prior to adhering the Fast Flash will void the warranty.
Installation Procedure
1. Before installing Fast Flash, make sure the roof is clean of dust and free of oils, grease, wax and detergents etc.
2. Cut the Fast Flash to length with roofing snips or a trade knife. Consider corners, change of direction and overlaps before cutting (See point 7 below)
3. Remove the backing paper to allow adhesion to the wall or the chimney etc.
4. The butyl adhesive backing has a 10 minute curing time, allowing adequate flexibility to reposition Fast Flash if required.
5. Once in correct position, remove the remaining backing paper and gently form the Fast Flash to the roof profile using your hands.
6. When required all lineal overlaps of Fast Flash must be 50mm in length & formed to the wall & roof profile in order to eliminate or minimise any gaps between the flashing and wall/tile.
7. Corners/change of direction - Using a trade knife, appropriately slice Fast Flash lengths to ensure a minimum corner/change in direction overlap of 40mm. Fold corner edges and form the roof profile in order to eliminate/minimise and gaps between the flashing and wall/tile.
8. Fast Flash is malleable and stretch-able, allowing easy folding around corners using hands.
9. When used on vertical surfaces with exposed brick or unpolished timber, a 25mm x 1mm Aluminium strip is recommended
10. For a professional finish, dress lightly using sand hammer.
For further Information go to https://3986358.app.netsuite.com/core/media/media.nl?id=4337732&c=3986358&h=c03bbfe8b13c8e70615b&_xt=.pdf
• Ideal for flashing of 2nd storeys to roofing below.
Suitable for use with tile, metal, polycarbonate & fibreglass materials.
Size | Pack Type | Colour | Code |
---|---|---|---|
280mm Wide x 5Mtr Roll |
|
||
370mm Wide x 5Mtr Roll |
|
||
560mm Wide x 5Mtr Roll |
|